Uniform Building Code |
From inside the book
Results 1-3 of 86
Page 115
In this system the required lateral forces are resisted by shear walls or braced frames as hereinafter defined . BRACED FRAME is a truss system or its equivalent which is provided to resist lateral forces in the frame system and in ...
In this system the required lateral forces are resisted by shear walls or braced frames as hereinafter defined . BRACED FRAME is a truss system or its equivalent which is provided to resist lateral forces in the frame system and in ...
Page 186
( h ) Lateral Support . Solid - sawn rectangular lumber beams , rafters and joists shall be supported laterally to prevent rotation or lateral displacement in accordance with the following : If the ratio of depth to thickness , based on ...
( h ) Lateral Support . Solid - sawn rectangular lumber beams , rafters and joists shall be supported laterally to prevent rotation or lateral displacement in accordance with the following : If the ratio of depth to thickness , based on ...
Page 525
in the earth may be used to resist both axial and lateral loads . The depth to resist lateral loads shall be determined by means of the design criteria established herein or other methods approved by the building official . 2.
in the earth may be used to resist both axial and lateral loads . The depth to resist lateral loads shall be determined by means of the design criteria established herein or other methods approved by the building official . 2.
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Definitions and Abbreviations | 17 |
Fireresistive Substitution | 33 |
Pedestrian Walkways | 34 |
Copyright | |
119 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved axial bars beam bearing bending building official Chapter column combination comply compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined direction distance Division edge effective elasticity elements equipment exceed EXCEPTION exit exterior walls face factor feet fiber fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal hour inches increased inspection installed joints lateral least length less limited live load located masonry materials maximum modulus nails Occupancies one-hour openings panel parallel percent permitted placed portion protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab space span specified square steel storage story strength stress Structural Stud surface Table tension thickness Type U.B.C. Standard unit values vertical walls welds wide width wood