Uniform Building Code |
From inside the book
Results 1-3 of 70
Page 109
... live load caused by the use to which the building or part of the building is to be put shall be used in the design ... load than specified for such use . ( b ) Distribution of Uniform Floor Loads . Where uniform floor loads are involved ...
... live load caused by the use to which the building or part of the building is to be put shall be used in the design ... load than specified for such use . ( b ) Distribution of Uniform Floor Loads . Where uniform floor loads are involved ...
Page 110
... live load is 20 pounds per square foot or more and the provisions of Section 2305 ( d ) are met . ( c ) Unbalanced Loading . Unbalanced loads shall be used where such loading will result in larger members or connections . Trusses and ...
... live load is 20 pounds per square foot or more and the provisions of Section 2305 ( d ) are met . ( c ) Unbalanced Loading . Unbalanced loads shall be used where such loading will result in larger members or connections . Trusses and ...
Page 126
... LOAD DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) Walkway , see Sec . 4406 150 Canopy , see Sec . 4407 150 Seats and See 1202 Footnote 3 CATEGORY 1. Construction , public access at site ( live load ) 2. Grandstands ...
... LOAD DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) Walkway , see Sec . 4406 150 Canopy , see Sec . 4407 150 Seats and See 1202 Footnote 3 CATEGORY 1. Construction , public access at site ( live load ) 2. Grandstands ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength