Uniform Building Code |
From inside the book
Results 1-3 of 75
Page 44
Division 3 Occupancies located in a basement or above the first story shall be of not less than one - hour fire - resistive construction . Group A assembly rooms having an occupant load of 1000 or more shall not be located in the ...
Division 3 Occupancies located in a basement or above the first story shall be of not less than one - hour fire - resistive construction . Group A assembly rooms having an occupant load of 1000 or more shall not be located in the ...
Page 85
Collectors located above or upon a roof and not functioning as building components shall not reduce the required fire resistance nor fire - retardancy classification of the roof covering materials . EXCEPTIONS : 1.
Collectors located above or upon a roof and not functioning as building components shall not reduce the required fire resistance nor fire - retardancy classification of the roof covering materials . EXCEPTIONS : 1.
Page 87
... separation which is adjacent to the atrium may be omitted between a Group B , Division 2 Occupancy office or sales area or Group A , Division 3 Occupancy and Group R , Division 1 apartment or guest room located on another level .
... separation which is adjacent to the atrium may be omitted between a Group B , Division 2 Occupancy office or sales area or Group A , Division 3 Occupancy and Group R , Division 1 apartment or guest room located on another level .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Definitions and Abbreviations | 17 |
Fireresistive Substitution | 33 |
Pedestrian Walkways | 34 |
Copyright | |
119 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved axial bars beam bearing bending building official Chapter column combination comply compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined direction distance Division edge effective elasticity elements equipment exceed EXCEPTION exit exterior walls face factor feet fiber fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal hour inches increased inspection installed joints lateral least length less limited live load located masonry materials maximum modulus nails Occupancies one-hour openings panel parallel percent permitted placed portion protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab space span specified square steel storage story strength stress Structural Stud surface Table tension thickness Type U.B.C. Standard unit values vertical walls welds wide width wood