Uniform Building Code |
From inside the book
Results 1-3 of 79
Page 29
... one and one - half - hour fire - protection rating . 3. A " two - hour fire - resistive occupancy separation " shall be of not less than two - hour fire - resistive construction . All openings in such separation shall be protected by a ...
... one and one - half - hour fire - protection rating . 3. A " two - hour fire - resistive occupancy separation " shall be of not less than two - hour fire - resistive construction . All openings in such separation shall be protected by a ...
Page 31
... hour fire - resistive walls and one and one - half - hour fire - protection rating in two - hour fire - resistive walls . 2. Area separation walls shall extend to the outer edges of horizontal projecting elements such as balconies ...
... hour fire - resistive walls and one and one - half - hour fire - protection rating in two - hour fire - resistive walls . 2. Area separation walls shall extend to the outer edges of horizontal projecting elements such as balconies ...
Page 43
... One- hour , Type IV or Type V One - hour construction shall not exceed 40 feet to the highest level of seat boards ; 20 feet in cases where construction is Type III - N or Type V - N ; and 12 feet in cases where construction is with ...
... One- hour , Type IV or Type V One - hour construction shall not exceed 40 feet to the highest level of seat boards ; 20 feet in cases where construction is Type III - N or Type V - N ; and 12 feet in cases where construction is with ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength