Page 300
... PANELS APPLIED OVER 1/2 " GYPSUM SHEATHING THICKNESS ( In . ) PANEL GRADE MINIMUM NOMINAL PANEL PENETRATION MINIMUM NAIL PANELS APPLIED DIRECT TO FRAMING Nail Size Nail Spacing at Panel Edges ( In . ) Nail Size Nail Spacing at Panel ...
... PANELS APPLIED OVER 1/2 " GYPSUM SHEATHING THICKNESS ( In . ) PANEL GRADE MINIMUM NOMINAL PANEL PENETRATION MINIMUM NAIL PANELS APPLIED DIRECT TO FRAMING Nail Size Nail Spacing at Panel Edges ( In . ) Nail Size Nail Spacing at Panel ...
Page 695
... Panels . Combinations of plastic glazing and plastic exterior wall panels shall be subject to the area , height , percentage and separation requirements applicable to the class of plastics as prescribed for wall panel installation . ( e ) ...
... Panels . Combinations of plastic glazing and plastic exterior wall panels shall be subject to the area , height , percentage and separation requirements applicable to the class of plastics as prescribed for wall panel installation . ( e ) ...
Page 697
... panels in the exterior wall and the maximum square feet of any individual panel may be increased 50 percent above ... Panels Sec . 5206. Approved plastic roof panels may be installed in roofs of buildings not required to have a fire ...
... panels in the exterior wall and the maximum square feet of any individual panel may be increased 50 percent above ... Panels Sec . 5206. Approved plastic roof panels may be installed in roofs of buildings not required to have a fire ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength