Uniform Building Code |
From inside the book
Results 1-3 of 91
Page 178
... parallel to grain . с = F ' allowable unit stress in compression parallel to grain adjusted for leld ratio where d is the least dimension . F ' C fc = actual unit stress in compression parallel to grain . = allowable unit stress in ...
... parallel to grain . с = F ' allowable unit stress in compression parallel to grain adjusted for leld ratio where d is the least dimension . F ' C fc = actual unit stress in compression parallel to grain . = allowable unit stress in ...
Page 284
... Parallel to Wide Faces of the Laminations Loaded Perpendicular to Wide Faces of Laminations Axially Loaded Extreme Fiber in Bending Compression Compression Perpen- dicular to Grain Compres- Extreme Compression Compres- Horizontal ...
... Parallel to Wide Faces of the Laminations Loaded Perpendicular to Wide Faces of Laminations Axially Loaded Extreme Fiber in Bending Compression Compression Perpen- dicular to Grain Compres- Extreme Compression Compres- Horizontal ...
Page 285
... parallel to the wide faces of the laminations Axially Loaded Tension Compres- Parallel Compression Parallel To Grain Extreme Fiber in Bending Bending About X - X Axis Loaded Perpendicular to Wide Faces of Laminations Extreme Fiber in ...
... parallel to the wide faces of the laminations Axially Loaded Tension Compres- Parallel Compression Parallel To Grain Extreme Fiber in Bending Bending About X - X Axis Loaded Perpendicular to Wide Faces of Laminations Extreme Fiber in ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength