Uniform Building Code |
From inside the book
Results 1-3 of 82
Page 35
... space not less than 30 inches in width and have a clear space in front of the water closet stool of not less than 24 inches . Where toilet facilities are provided on any floor where access by the physically handicapped is required by ...
... space not less than 30 inches in width and have a clear space in front of the water closet stool of not less than 24 inches . Where toilet facilities are provided on any floor where access by the physically handicapped is required by ...
Page 121
... space frames may be enclosed by or adjoined by more rigid elements which would tend to prevent the space frame from resisting lateral forces where it can be shown that the action or failure of the more rigid elements will not impair the ...
... space frames may be enclosed by or adjoined by more rigid elements which would tend to prevent the space frame from resisting lateral forces where it can be shown that the action or failure of the more rigid elements will not impair the ...
Page 203
... space , and shall subdivide attic spaces , concealed roof spaces and floor - ceiling assemblies . The integrity of all fire and draft stops shall be maintained . 2. Fire stops , where required . Firestopping shall be provided in the ...
... space , and shall subdivide attic spaces , concealed roof spaces and floor - ceiling assemblies . The integrity of all fire and draft stops shall be maintained . 2. Fire stops , where required . Firestopping shall be provided in the ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength