Page 64
... square feet or more and not less than one - hour fire - resistive construction when the area is less than 300 square feet . The provisions of Section 503 ( a ) shall apply . When an HPM storage room is also used for dispensing of Class ...
... square feet or more and not less than one - hour fire - resistive construction when the area is less than 300 square feet . The provisions of Section 503 ( a ) shall apply . When an HPM storage room is also used for dispensing of Class ...
Page 74
... feet above the floor . If any room in a building has a sloping ceiling , the prescribed ceiling height for the room ... square feet of floor area . Other habitable rooms except kitchens shall have an area of not less than 70 square feet ...
... feet above the floor . If any room in a building has a sloping ceiling , the prescribed ceiling height for the room ... square feet of floor area . Other habitable rooms except kitchens shall have an area of not less than 70 square feet ...
Page 736
... square feet in total floor area shall be provided with a public address system accessible for use by the fire department . Covered mall buildings of 50,000 square feet or less in total floor area , when provided with a public address ...
... square feet in total floor area shall be provided with a public address system accessible for use by the fire department . Covered mall buildings of 50,000 square feet or less in total floor area , when provided with a public address ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength