Uniform Building Code |
From inside the book
Results 1-3 of 42
Page 564
... Stairways . When a basement stairway and a stairway to an upper story terminate in the same exit enclosure , an approved barrier shall be provided to prevent persons from continuing on into the basement . Directional exit signs shall be ...
... Stairways . When a basement stairway and a stairway to an upper story terminate in the same exit enclosure , an approved barrier shall be provided to prevent persons from continuing on into the basement . Directional exit signs shall be ...
Page 567
... Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and shall also include a corridor on the ground floor leading from the stairway to the exterior of the building . Enclosed corridors or ...
... Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and shall also include a corridor on the ground floor leading from the stairway to the exterior of the building . Enclosed corridors or ...
Page 727
... stairway doors . Exit doors into exit stairway enclosures shall be maintained unlocked from the stairway side on at least every fifth floor level . All unlocked doors shall bear a sign stating ACCESS ONTO FLOOR THIS LEVEL . Stairway ...
... stairway doors . Exit doors into exit stairway enclosures shall be maintained unlocked from the stairway side on at least every fifth floor level . All unlocked doors shall bear a sign stating ACCESS ONTO FLOOR THIS LEVEL . Stairway ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength