Uniform Building Code |
From inside the book
Results 1-3 of 93
Page 2
... structure which are nonstruc- tural and do not adversely affect any structural member or any part of the building or structure having required fire resistance may be made with the same materials of which the building or structure is ...
... structure which are nonstruc- tural and do not adversely affect any structural member or any part of the building or structure having required fire resistance may be made with the same materials of which the building or structure is ...
Page 113
... structure may be , designed in accordance with approved national standards . ( b ) Basic Wind Speed . The minimum basic wind speed for determining design wind pressure shall be taken from Figure No. 4. Where terrain features and local ...
... structure may be , designed in accordance with approved national standards . ( b ) Basic Wind Speed . The minimum basic wind speed for determining design wind pressure shall be taken from Figure No. 4. Where terrain features and local ...
Page 758
... structure . AIR - SUPPORTED STRUCTURE is a building wherein the shape of the structure is attained by air pressure and occupants of the structure are within the elevated pressure area . Air - supported structures are of two basic types ...
... structure . AIR - SUPPORTED STRUCTURE is a building wherein the shape of the structure is attained by air pressure and occupants of the structure are within the elevated pressure area . Air - supported structures are of two basic types ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength