Uniform Building Code |
From inside the book
Results 1-3 of 87
Page 74
... Units Sec . 1208. An efficiency dwelling unit shall conform to the requirements of the code except as herein provided : 1. The unit shall have a living room of not less than 220 square feet of superficial floor area . An additional 100 ...
... Units Sec . 1208. An efficiency dwelling unit shall conform to the requirements of the code except as herein provided : 1. The unit shall have a living room of not less than 220 square feet of superficial floor area . An additional 100 ...
Page 139
... units in the same wythe , usually vertical . MASONRY UNIT is brick , tile , stone , glass block or concrete block conform- ing to the requirements specified in Section 2402 . Hollow masonry unit is a masonry unit whose net cross ...
... units in the same wythe , usually vertical . MASONRY UNIT is brick , tile , stone , glass block or concrete block conform- ing to the requirements specified in Section 2402 . Hollow masonry unit is a masonry unit whose net cross ...
Page 178
... unit stress for extreme fiber in bending . F'b F fb = allowable unit stress for extreme fiber in bending , adjusted for slender- ness . = actual unit stress for extreme fiber in bending . F = allowable unit stress in compression ...
... unit stress for extreme fiber in bending . F'b F fb = allowable unit stress for extreme fiber in bending , adjusted for slender- ness . = actual unit stress for extreme fiber in bending . F = allowable unit stress in compression ...
Contents
Organization and Enforcement | 4 |
Part IIDefinitions and Abbreviations | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
103 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section Allowable Unit Stresses applied approved atrium axial load bars beam bolts building official building or structure column comply compression members concrete conform dead load deflection diameter diaphragms Division 1 Occupancies exceed exit exterior walls extreme fiber factor Fire Code floor area Formula framing girders grade Group H grout height horizontal shear inspection installed joints joists laminations lateral forces length less live load located lumber materials maximum minimum modulus of elasticity nails noncombustible occupancy separation openings panel Parallel to Grain particleboard partitions percent permitted perpendicular plywood portion pounds per square prestressing protected psi psi psi ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel storage strength Stud Table tensile tensile stress tension thickness U.B.C. Standard vertical welds width wood yield strength