Uniform Building Code |
From inside the book
Results 1-3 of 87
Page 74
Every dwelling unit shall have at least one room which shall have not less than 120 square feet of floor area . Other habitable rooms except kitchens shall have an area of not less than 70 square feet . Efficiency dwelling units shall ...
Every dwelling unit shall have at least one room which shall have not less than 120 square feet of floor area . Other habitable rooms except kitchens shall have an area of not less than 70 square feet . Efficiency dwelling units shall ...
Page 139
JOINTS : Bed joint is the mortar joint that is horizontal at the time the masonry units are placed . ... MASONRY UNIT is brick , tile , stone , glass block or concrete block conforming to the requirements specified in Section 2402 .
JOINTS : Bed joint is the mortar joint that is horizontal at the time the masonry units are placed . ... MASONRY UNIT is brick , tile , stone , glass block or concrete block conforming to the requirements specified in Section 2402 .
Page 178
E e = modulus of elasticity . eccentricity allowable unit stress for extreme fiber in bending . = allowable unit stress for extreme fiber in bending , adjusted for slenderFь Fo ness . rc fre fr fь = actual unit stress for extreme fiber ...
E e = modulus of elasticity . eccentricity allowable unit stress for extreme fiber in bending . = allowable unit stress for extreme fiber in bending , adjusted for slenderFь Fo ness . rc fre fr fь = actual unit stress for extreme fiber ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Definitions and Abbreviations | 17 |
Fireresistive Substitution | 33 |
Pedestrian Walkways | 34 |
Copyright | |
119 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved axial bars beam bearing bending building official Chapter column combination comply compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined direction distance Division edge effective elasticity elements equipment exceed EXCEPTION exit exterior walls face factor feet fiber fire fire-resistive flexural floor foot forces Formula framing grade grain greater Group height horizontal hour inches increased inspection installed joints lateral least length less limited live load located masonry materials maximum modulus nails Occupancies one-hour openings panel parallel percent permitted placed portion protected ratio reinforcement resist roof rooms Section Select Structural separation shear side slab space span specified square steel storage story strength stress Structural Stud surface Table tension thickness Type U.B.C. Standard unit values vertical walls welds wide width wood