Uniform Building Code Standards |
From inside the book
Results 1-3 of 76
Page 68
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 24-10 STRUCTURAL CLAY FLOOR TILE Based on Standard Specification C57-65 of the American Society for Testing and Materials Scope See Section 2403 ( f ) ...
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 24-10 STRUCTURAL CLAY FLOOR TILE Based on Standard Specification C57-65 of the American Society for Testing and Materials Scope See Section 2403 ( f ) ...
Page 148
... requirements , the appropri- ate provisions of all other sections in this standard apply . UNIFORM BUILDING CODE STANDARD NO . 25-5 EASTERN WOODS , EASTERN WHITE PINE , RED PINE , EASTERN SPRUCE , BALSAM FIR , ASPEN ( BIGTOOTH QUAKING ) ...
... requirements , the appropri- ate provisions of all other sections in this standard apply . UNIFORM BUILDING CODE STANDARD NO . 25-5 EASTERN WOODS , EASTERN WHITE PINE , RED PINE , EASTERN SPRUCE , BALSAM FIR , ASPEN ( BIGTOOTH QUAKING ) ...
Page 508
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 26-8 WELDING REINFORCING STEEL , METAL INSERTS AND CONNECTIONS IN REINFORCED CONCRETE CONSTRUCTION Based on Standard Specification AWS D1.4-79 of the ...
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 26-8 WELDING REINFORCING STEEL , METAL INSERTS AND CONNECTIONS IN REINFORCED CONCRETE CONSTRUCTION Based on Standard Specification AWS D1.4-79 of the ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone