Uniform Building Code Standards |
From inside the book
Results 1-3 of 65
Page 94
... Figure No. 25-1-1 ) . A corner knot in a joist containing the pith is measured either by its width on the narrow face between lines parallel to the edge , or by its smallest diameter on the wide face , whichever is more restrictive ...
... Figure No. 25-1-1 ) . A corner knot in a joist containing the pith is measured either by its width on the narrow face between lines parallel to the edge , or by its smallest diameter on the wide face , whichever is more restrictive ...
Page 754
... Figure No. 27-6-51 ) . C. The search unit shall produce a sound beam in the material being tested within plus or minus 2 degrees of the following proper angles : 70 degrees , 60 degrees or 45 degrees , as described in Section 27.620 ( j ) ...
... Figure No. 27-6-51 ) . C. The search unit shall produce a sound beam in the material being tested within plus or minus 2 degrees of the following proper angles : 70 degrees , 60 degrees or 45 degrees , as described in Section 27.620 ( j ) ...
Page 1323
... Figure No. 54-2-1 . The clamping frame for securing the test specimen on all four edges shall be reinforced at the corners . See Detail A of Figure No. 54-2-1 . Other materials may be used , provided there is positive assurance that the ...
... Figure No. 54-2-1 . The clamping frame for securing the test specimen on all four edges shall be reinforced at the corners . See Detail A of Figure No. 54-2-1 . Other materials may be used , provided there is positive assurance that the ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone