Uniform Building Code Standards |
From inside the book
Results 1-3 of 63
Page 485
... bars for concrete , as set forth in Table No. 26-4 - A . Definition of Deformed Bar Sec . 26.402 . DEFORMED BAR is any deformed steel bar intended for use as rein- forcement in reinforced concrete construction , and of which the surface ...
... bars for concrete , as set forth in Table No. 26-4 - A . Definition of Deformed Bar Sec . 26.402 . DEFORMED BAR is any deformed steel bar intended for use as rein- forcement in reinforced concrete construction , and of which the surface ...
Page 490
... bars to be used for the reinforcement of concrete . Such mats shall consist of two layers of bars which are assembled at right angles to each other and clipped or welded at the intersections to form a rectangular grid . Bar Material Sec ...
... bars to be used for the reinforcement of concrete . Such mats shall consist of two layers of bars which are assembled at right angles to each other and clipped or welded at the intersections to form a rectangular grid . Bar Material Sec ...
Page 510
... bars whose axes are approximately colinear , and the bars are joined by a complete joint penetration groove weld which has been made from both sides or from one side with backing , having complete penetration and fusion of weld and base ...
... bars whose axes are approximately colinear , and the bars are joined by a complete joint penetration groove weld which has been made from both sides or from one side with backing , having complete penetration and fusion of weld and base ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone