Page 315
... Coating . Hand - driven staples or nails required to be zinc coated shall be cut and formed from hot - dip ... coating : 1. Galvanizing . Hot - dip galvanizing of wire shall produce coating weights in accordance with Table No. 25-17 - U ...
... Coating . Hand - driven staples or nails required to be zinc coated shall be cut and formed from hot - dip ... coating : 1. Galvanizing . Hot - dip galvanizing of wire shall produce coating weights in accordance with Table No. 25-17 - U ...
Page 961
... coating shall have a penetration of not less than 13 as determined by Penetration Test - Asphaltic Material in Coating . See Section 32.313 . The coating shall be uniformly distributed over and completely cover both sides of the ...
... coating shall have a penetration of not less than 13 as determined by Penetration Test - Asphaltic Material in Coating . See Section 32.313 . The coating shall be uniformly distributed over and completely cover both sides of the ...
Page 991
... coating . The quantity should be not less than 1.2 quarts per ounce of zinc coating on the specimen and shall be sufficient to cover the specimen so that the top surface of the solution is at least 1⁄2 inch above the top of the section ...
... coating . The quantity should be not less than 1.2 quarts per ounce of zinc coating on the specimen and shall be sufficient to cover the specimen so that the top surface of the solution is at least 1⁄2 inch above the top of the section ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone