Uniform Building Code Standards |
From inside the book
Results 1-3 of 73
Page 3
... Covers the fire , life and structural safety aspects of all buildings and related structures . Uniform Building Code Standards . Presents in a compact and concise man- ner national test , material and special design standards referred ...
... Covers the fire , life and structural safety aspects of all buildings and related structures . Uniform Building Code Standards . Presents in a compact and concise man- ner national test , material and special design standards referred ...
Page 1125
... Covers . An enclosure cover of an air - sampling - type detector shall be hinged , sliding , pivoted or similarly attached if : ( 1 ) it provides ready access to fuses or any other overcurrent protective device , the normal functioning ...
... Covers . An enclosure cover of an air - sampling - type detector shall be hinged , sliding , pivoted or similarly attached if : ( 1 ) it provides ready access to fuses or any other overcurrent protective device , the normal functioning ...
Page 1129
... covers which do not enclose uninsulated live parts if wiring is positively separated from the panel or cover so that it is not liable to become energized . 4. Panels and covers which are insulated from electrical components and wiring ...
... covers which do not enclose uninsulated live parts if wiring is positively separated from the panel or cover so that it is not liable to become energized . 4. Panels and covers which are insulated from electrical components and wiring ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone