Uniform Building Code Standards |
From inside the book
Results 1-3 of 68
Page 454
... Dimensions . Particleboards are generally made in panels measuring 4 feet wide by 8 feet long and larger and in thickness ranging from 8 inch to 2 inches . Dimensions of trimmed panels shall be measured in accordance with Section ...
... Dimensions . Particleboards are generally made in panels measuring 4 feet wide by 8 feet long and larger and in thickness ranging from 8 inch to 2 inches . Dimensions of trimmed panels shall be measured in accordance with Section ...
Page 644
... Dimensions of groove welds specified on design or detail drawings may vary from the dimensions shown in Figure No. 27-6-3 only within the following limits : A. The groove angle is minimum . It may be detailed to exceed the dimension ...
... Dimensions of groove welds specified on design or detail drawings may vary from the dimensions shown in Figure No. 27-6-3 only within the following limits : A. The groove angle is minimum . It may be detailed to exceed the dimension ...
Page 1326
... dimensions of test specimens to 0.001 inch . G. Cold box . A cold box capable of maintaining the required temperature of test within ± 5.4 ° F . 3. Procedure . The four plastic specimens shall be subjected to ten complete humid / dry ...
... dimensions of test specimens to 0.001 inch . G. Cold box . A cold box capable of maintaining the required temperature of test within ± 5.4 ° F . 3. Procedure . The four plastic specimens shall be subjected to ten complete humid / dry ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone