Uniform Building Code Standards |
From inside the book
Results 1-3 of 80
Page 134
... equivalent ; splits approximately one half the width or equivalent of end checks ; seasoning checks in areas at ends , single or opposite each other , are limited to a sum total of one fourth the thickness ; limited pinholes ; heavy ...
... equivalent ; splits approximately one half the width or equivalent of end checks ; seasoning checks in areas at ends , single or opposite each other , are limited to a sum total of one fourth the thickness ; limited pinholes ; heavy ...
Page 135
... equivalent ; splits equal to three fourths the thickness or equivalent end checks ; seasoning checks in areas at ends , single or opposite each other , are limited to a sum total of one half the thickness ; limited pinholes ; heavy torn ...
... equivalent ; splits equal to three fourths the thickness or equivalent end checks ; seasoning checks in areas at ends , single or opposite each other , are limited to a sum total of one half the thickness ; limited pinholes ; heavy torn ...
Page 139
... equivalent smaller are permitted for each 12 feet of length . Spike knots are permitted if judged equivalent to other knots . 3. Standard . Boards of this grade are graded chiefly for serviceability . Characteristics and limiting ...
... equivalent smaller are permitted for each 12 feet of length . Spike knots are permitted if judged equivalent to other knots . 3. Standard . Boards of this grade are graded chiefly for serviceability . Characteristics and limiting ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone