... feet by 12 feet having a ceiling height of 8 feet located in an enclosed building . A doorway 2 feet 6 inches by 7 feet 0 inches shall be centered in one of the 8 - foot - long walls of the test structure . See Figure No. 1 . The wall ...
... feet by 12 feet having a ceiling height of 8 feet located in an enclosed building . A doorway 2 feet 6 inches by 7 feet 0 inches shall be centered in one of the 8 - foot - long walls of the test structure . See Figure No. 1 . The wall ...
Page 289
... feet from the butt and in the outer 3 inches of poles having a circumference of more than 37.5 inches at 6 feet from the butt shall be not less than six rings per inch . EXCEPTION : Poles with four and five rings per inch are acceptable ...
... feet from the butt and in the outer 3 inches of poles having a circumference of more than 37.5 inches at 6 feet from the butt shall be not less than six rings per inch . EXCEPTION : Poles with four and five rings per inch are acceptable ...
Page 290
... feet below the ground line is not less than the minimum circumference specified at 6 feet from the butt for the class and length of the pole ; and 2. That the depth of the trimmed scar is not more than 2 inches , if the diameter is 10 ...
... feet below the ground line is not less than the minimum circumference specified at 6 feet from the butt for the class and length of the pole ; and 2. That the depth of the trimmed scar is not more than 2 inches , if the diameter is 10 ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone