Uniform Building Code Standards |
From inside the book
Results 1-3 of 49
Page 509
... welds and fillet welds shall be in accordance with Table No. 26-8 - A . Except as specified in Column G of Table No. 26-8 - A , the proper electrode classification as shown in Table No. 26-8 - C shall be used for a given base metal ...
... welds and fillet welds shall be in accordance with Table No. 26-8 - A . Except as specified in Column G of Table No. 26-8 - A , the proper electrode classification as shown in Table No. 26-8 - C shall be used for a given base metal ...
Page 643
... Fillet Welds . 1. The details of fillet welds made by shielded metal arc , submerged arc , gas metal arc or flux cored arc welding to be used without joint - welding procedure qualification are described in Sections 2714 ( b ) through ...
... Fillet Welds . 1. The details of fillet welds made by shielded metal arc , submerged arc , gas metal arc or flux cored arc welding to be used without joint - welding procedure qualification are described in Sections 2714 ( b ) through ...
Page 692
... Welding with a Single Electrode . 1. All sub- merged arc welds except fillet welds shall be made in the flat position . Fillet welds may be made in either the flat or horizontal position , except that single pass fillet welds made in ...
... Welding with a Single Electrode . 1. All sub- merged arc welds except fillet welds shall be made in the flat position . Fillet welds may be made in either the flat or horizontal position , except that single pass fillet welds made in ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone