... Glued - laminated Members and Laminations Preservative Treatment After Gluing Sec . 25.1209 . ( a ) General . After gluing , structural glued - laminated members shall be treated in accordance with these standards except as modified or ...
... Glued - laminated Members and Laminations Preservative Treatment After Gluing Sec . 25.1209 . ( a ) General . After gluing , structural glued - laminated members shall be treated in accordance with these standards except as modified or ...
Page 376
... glued to each other in any member shall not exceed 5 percent . 4. Surface requirements . Surfaces of plywood to be glued shall be clean and free from oil , dust , paper tape and other material which would be detrimental to satisfactory ...
... glued to each other in any member shall not exceed 5 percent . 4. Surface requirements . Surfaces of plywood to be glued shall be clean and free from oil , dust , paper tape and other material which would be detrimental to satisfactory ...
Page 377
... glued splice plates . Flange laminations of beams having glue lines parallel to the web may be glued at the same time as webs or preassembled . In either case , the laminating shall conform to the applicable requirements of U.B.C. ...
... glued splice plates . Flange laminations of beams having glue lines parallel to the web may be glued at the same time as webs or preassembled . In either case , the laminating shall conform to the applicable requirements of U.B.C. ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone