Page 91
... grading of lumber shall be uniform . Grading rules shall be sufficiently explicit to establish a maximum of 5 percent below grade as a reasonable variation between graders . If any grading rules indicate that a grade qualifies under two ...
... grading of lumber shall be uniform . Grading rules shall be sufficiently explicit to establish a maximum of 5 percent below grade as a reasonable variation between graders . If any grading rules indicate that a grade qualifies under two ...
Page 777
... Grade B AH 32 & 36 ASTM A573 Grade 65 DH 32 & 36 ASTM A588 EH 32 & 36 ASTM A595 Grades A , ASTM A139 Grade B B , C ASTM A242 ASTM A606 ASTM A381 Grade Y35 ASTM A607 Grades 45 , ASTM A441 50 , 55 ASTM A500 Grade A Grade B ASTM A618 ASTM ...
... Grade B AH 32 & 36 ASTM A573 Grade 65 DH 32 & 36 ASTM A588 EH 32 & 36 ASTM A595 Grades A , ASTM A139 Grade B B , C ASTM A242 ASTM A606 ASTM A381 Grade Y35 ASTM A607 Grades 45 , ASTM A441 50 , 55 ASTM A500 Grade A Grade B ASTM A618 ASTM ...
Page 900
... Grade A 33 230 45 310 Grade B 37 255 52 360 Grade C 40 275 55 380 A570 Grade A 25 175 45 310 Grade B 30 205 49 340 Grade C 33 230 52 360 Grade D 40 275 55 380 Grade E 42 290 58 400 A606 45 310 65 450 A607 Grade 45 45 310 60 415 Grade 50 ...
... Grade A 33 230 45 310 Grade B 37 255 52 360 Grade C 40 275 55 380 A570 Grade A 25 175 45 310 Grade B 30 205 49 340 Grade C 33 230 52 360 Grade D 40 275 55 380 Grade E 42 290 58 400 A606 45 310 65 450 A607 Grade 45 45 310 60 415 Grade 50 ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone