Uniform Building Code Standards |
From inside the book
Results 1-3 of 78
Page 131
... Hole Pin , 15 per each square foot or four medium holes in a 1 - inch by 8 - inch by 12 - foot piece . Pitch - Heavy over one half the area or two small streaks of massed pitch . Pockets Medium , well distributed . Shake -- Light to ...
... Hole Pin , 15 per each square foot or four medium holes in a 1 - inch by 8 - inch by 12 - foot piece . Pitch - Heavy over one half the area or two small streaks of massed pitch . Pockets Medium , well distributed . Shake -- Light to ...
Page 585
... Holes for Rivets and Bolts . Holes for rivets or bolts shall be 16 inch larger than their nominal diameter except for oversized holes , short and long slotted holes as defined in U.B.C. Standard No. 27-7 and Section 27.202 ( a ) of this ...
... Holes for Rivets and Bolts . Holes for rivets or bolts shall be 16 inch larger than their nominal diameter except for oversized holes , short and long slotted holes as defined in U.B.C. Standard No. 27-7 and Section 27.202 ( a ) of this ...
Page 917
... holes extending across the part in any straight or broken line shall be obtained by deducting from the gross width the sum of the diameters of all the holes in the chain and adding s2 / 4g for each gage space in the chain . In the cor ...
... holes extending across the part in any straight or broken line shall be obtained by deducting from the gross width the sum of the diameters of all the holes in the chain and adding s2 / 4g for each gage space in the chain . In the cor ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone