Uniform Building Code Standards |
From inside the book
Results 1-3 of 77
Page 93
... measured and limited at the zone in the length of a structural timber that shows the greatest slope . It shall be measured over a distance sufficiently great to define the general slope , disregarding such short local deviations as ...
... measured and limited at the zone in the length of a structural timber that shows the greatest slope . It shall be measured over a distance sufficiently great to define the general slope , disregarding such short local deviations as ...
Page 94
... measured either by its width on the narrow face between lines parallel to the edge , or by its smallest diameter on ... measured on the wide face . The size of a knot on the wide face is measured by its smallest diameter ( see Figure No ...
... measured either by its width on the narrow face between lines parallel to the edge , or by its smallest diameter on ... measured on the wide face . The size of a knot on the wide face is measured by its smallest diameter ( see Figure No ...
Page 95
... Measured the same as for joists and planks . ( d ) Shakes , Checks and Splits . Shakes are measured at the ends of the piece . The size of a shake is the distance between lines enclosing the shake and parallel to the wide face of the ...
... Measured the same as for joists and planks . ( d ) Shakes , Checks and Splits . Shakes are measured at the ends of the piece . The size of a shake is the distance between lines enclosing the shake and parallel to the wide face of the ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone