Uniform Building Code Standards |
From inside the book
Results 1-3 of 42
Page 204
... tension test requirements : 1. Twenty test specimens of plain scarf joints with a slope of one in eight or flatter ... outer tension zone laminations of the following listed combinations shall be those that have been qualified for a ...
... tension test requirements : 1. Twenty test specimens of plain scarf joints with a slope of one in eight or flatter ... outer tension zone laminations of the following listed combinations shall be those that have been qualified for a ...
Page 256
... tension laminations are used in conjunction with L2 , L2D or L3 outer tension zone laminations , the required slope of grain is 1:12 as indicated in Section 25.1007 ( f ) . Dense No. 1 No. 1 . LICL L2D No. 2. ' The combinations in this ...
... tension laminations are used in conjunction with L2 , L2D or L3 outer tension zone laminations , the required slope of grain is 1:12 as indicated in Section 25.1007 ( f ) . Dense No. 1 No. 1 . LICL L2D No. 2. ' The combinations in this ...
Page 264
... TENSION LAMI- NATION3 3 Outer Inner Inner Outer Outer Tension Inner Tension Zone Inner Comp . Outer Comp . Tension Zone 4 Core 6 Zone B - 16F - V1 4 lams to < 12 in . 302-20 30 % / L2 / CR 5 The following combination is for all ...
... TENSION LAMI- NATION3 3 Outer Inner Inner Outer Outer Tension Inner Tension Zone Inner Comp . Outer Comp . Tension Zone 4 Core 6 Zone B - 16F - V1 4 lams to < 12 in . 302-20 30 % / L2 / CR 5 The following combination is for all ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone