Uniform Building Code Standards |
From inside the book
Results 1-3 of 65
Page 321
... Plate Connected Wood Trusses , TPI - 68 of the Truss Plate Institute Scope Sec . 25.1733 . This standard shall cover requirements for the manufacture of light metal plate connectors and the design and fabrication of metal plate ...
... Plate Connected Wood Trusses , TPI - 68 of the Truss Plate Institute Scope Sec . 25.1733 . This standard shall cover requirements for the manufacture of light metal plate connectors and the design and fabrication of metal plate ...
Page 563
... Plates . Neat cement caps and high - strength gypsum plaster caps shall be formed against a glass plate at least 1⁄4 inch thick , a machined metal plate at least 1⁄2 inch thick , or a polished plate of granite or diabase at least 3 ...
... Plates . Neat cement caps and high - strength gypsum plaster caps shall be formed against a glass plate at least 1⁄4 inch thick , a machined metal plate at least 1⁄2 inch thick , or a polished plate of granite or diabase at least 3 ...
Page 925
... Plate 0.018-2.000 18 14 -H14 Sheet & Plate 0.009-1.000 21 17 15 -H16 Sheet 0.006-0.162 24 20 -H32 Sheet & Plate 0.017-2.000 17 12 -H34 Sheet & Plate 0.009-1.000 20 15 -H36 Sheet 0.006-0.162 23 18 121123 338146 8 34 10 40 12 48 7 34 8.5 ...
... Plate 0.018-2.000 18 14 -H14 Sheet & Plate 0.009-1.000 21 17 15 -H16 Sheet 0.006-0.162 24 20 -H32 Sheet & Plate 0.017-2.000 17 12 -H34 Sheet & Plate 0.009-1.000 20 15 -H36 Sheet 0.006-0.162 23 18 121123 338146 8 34 10 40 12 48 7 34 8.5 ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone