Page 93
... Slope of Grain . Slope of grain resulting from either diagonal sawing or from spiral or twisted grain in the tree is measured by the angle between the direction of the fibers and the edge of the piece . The angle is expressed as a slope ...
... Slope of Grain . Slope of grain resulting from either diagonal sawing or from spiral or twisted grain in the tree is measured by the angle between the direction of the fibers and the edge of the piece . The angle is expressed as a slope ...
Page 125
... slope of grain not more than 1 inch in a length of 15 inches . MEDIUM CROSS GRAIN , slope of grain more than 1 inch in a length of 15 inches , but not more than 1 inch in a length of 8 inches . STEEP CROSS GRAIN , slope of grain more ...
... slope of grain not more than 1 inch in a length of 15 inches . MEDIUM CROSS GRAIN , slope of grain more than 1 inch in a length of 15 inches , but not more than 1 inch in a length of 8 inches . STEEP CROSS GRAIN , slope of grain more ...
Page 224
International Conference of Building Officials. Slope of Grain Sec . 25.1117 . Slope of grain shall be limited in the full length of each lamination and shall be measured over a distance sufficiently great to determine the general slope ...
International Conference of Building Officials. Slope of Grain Sec . 25.1117 . Slope of grain shall be limited in the full length of each lamination and shall be measured over a distance sufficiently great to determine the general slope ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone