Uniform Building Code Standards |
From inside the book
Results 1-3 of 78
Page 497
... tensile properties : Tensile strength , minimum , psi . Yield strength , minimum , psi . 85,000 75,000 For material to be used in the fabrication of welded fabric , the following tensile and yield strength properties shall apply ...
... tensile properties : Tensile strength , minimum , psi . Yield strength , minimum , psi . 85,000 75,000 For material to be used in the fabrication of welded fabric , the following tensile and yield strength properties shall apply ...
Page 814
... tensile tests ; ( 2 ) approved stub column tests ; or ( 3 ) computed as follows : Fy ya = CF + ( 1 − C ) Fyf ус WHERE : Fya C Fyc Fyf Вс = = average tensile yield point of the steel in the full section of compression members , or full ...
... tensile tests ; ( 2 ) approved stub column tests ; or ( 3 ) computed as follows : Fy ya = CF + ( 1 − C ) Fyf ус WHERE : Fya C Fyc Fyf Вс = = average tensile yield point of the steel in the full section of compression members , or full ...
Page 1325
... tensile tester with the moving crosshead set to move at 12 inches per minute and load range such that the average peel force will fall at 30 percent to 50 percent of full scale , and a cutter containing new razor blades for cutting 1 ...
... tensile tester with the moving crosshead set to move at 12 inches per minute and load range such that the average peel force will fall at 30 percent to 50 percent of full scale , and a cutter containing new razor blades for cutting 1 ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone