Uniform Building Code Standards |
From inside the book
Results 1-3 of 76
Page 63
... thickness of wall when their combined width is not less than 1⁄2 inch , provided the short webs between the inner and outer shells are not greater in number or thickness than the long transverse webs holding the inner shells . Re ...
... thickness of wall when their combined width is not less than 1⁄2 inch , provided the short webs between the inner and outer shells are not greater in number or thickness than the long transverse webs holding the inner shells . Re ...
Page 176
International Conference of Building Officials. % inch rough ( unsanded ) thickness or over ; 12 inch or thicker in panels of lesser thickness . In no case shall veneers used in face or back layers be thicker than 1⁄4 inch , or veneers ...
International Conference of Building Officials. % inch rough ( unsanded ) thickness or over ; 12 inch or thicker in panels of lesser thickness . In no case shall veneers used in face or back layers be thicker than 1⁄4 inch , or veneers ...
Page 728
... thickness of the test plate welded . If the test plate is 1 inch or greater in thickness , the welder will be qualified for all thicknesses . The welder is also qualified for fillet welding of plate and pipe as shown in Table No. 27-6 ...
... thickness of the test plate welded . If the test plate is 1 inch or greater in thickness , the welder will be qualified for all thicknesses . The welder is also qualified for fillet welding of plate and pipe as shown in Table No. 27-6 ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone