... unit in square inches . The gross area of a unit is the total area of a section perpendicular to the direction of the load , including areas within cells and within re - entrant spaces unless these spaces are to be occupied in the ...
... unit in square inches . The gross area of a unit is the total area of a section perpendicular to the direction of the load , including areas within cells and within re - entrant spaces unless these spaces are to be occupied in the ...
Page 483
... Unit Weights . It shall be impossible to produce structural concrete using the lightweight aggregates under test such that from the same batch of concrete one or more of the compressive strength requirements and the splitting tensile ...
... Unit Weights . It shall be impossible to produce structural concrete using the lightweight aggregates under test such that from the same batch of concrete one or more of the compressive strength requirements and the splitting tensile ...
Page 754
... units shall consist of a transducer and an angle wedge . The unit may be comprised of the two separate elements or may be an integral unit . A. The transducer frequency shall be between 2 and 2.5 MHz , inclusive . B. The transducer ...
... units shall consist of a transducer and an angle wedge . The unit may be comprised of the two separate elements or may be an integral unit . A. The transducer frequency shall be between 2 and 2.5 MHz , inclusive . B. The transducer ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone