Uniform Building Code Standards |
From inside the book
Results 1-3 of 72
Page 573
... weight ( dry ) of cement and of fine and coarse aggregates that are proposed to be used in the manufacture of each class of concrete , the water content , the type and amount of admixture , and the maximum and minimum limits of air ...
... weight ( dry ) of cement and of fine and coarse aggregates that are proposed to be used in the manufacture of each class of concrete , the water content , the type and amount of admixture , and the maximum and minimum limits of air ...
Page 955
International Conference of Building Officials. If the average weight and the individual weights of the first five rolls are accep- table , accept that lot . If the average weight of the first five rolls is acceptable but the weight of ...
International Conference of Building Officials. If the average weight and the individual weights of the first five rolls are accep- table , accept that lot . If the average weight of the first five rolls is acceptable but the weight of ...
Page 980
... weight of each package selected shall be obtained and the average of the lot shall be deter- mined . These weights ... weight of shingles per 100 square feet may be calculated by using the following formula : W = P AX N × 100 WHERE : W ...
... weight of each package selected shall be obtained and the average of the lot shall be deter- mined . These weights ... weight of shingles per 100 square feet may be calculated by using the following formula : W = P AX N × 100 WHERE : W ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch 16 inch accordance adhesive admixture aggregate allowable load applied ASTM average axis base metal beam bending bolt BUILDING CODE STANDARD building official butt butt joints cement combination compression compression members concrete conform connectors cross section depth determined diameter dimensions distance Douglas fir E-rated edge electrode exceed feet fillet welds flange grade groove welds holes horizontal joists knots laminations lams length less limited lumber material maximum medium minimum modulus modulus of elasticity moisture content nominal panel parallel percent permitted perpendicular piece pine pitch plate plywood portland cement pounds per square pozzolan procedure qualification ratio requirements sample shear shear stress slope of grain spacing specified splice square inch stiffeners structural stud submerged arc welding surface Table temperature tensile tensile strength tension test specimens thickness Type U.B.C. Standard Uniform Building Code values weight wide face width wire yield strength Zone