CABO One and Two Family Dwelling Code |
From inside the book
Results 1-3 of 95
Page 9
... less than 7 feet . Section R - 205 - Room Sizes Every dwelling unit shall have at least one habitable room which shall have not less than 150 square feet of floor area . Other habitable rooms shall have an area of not less than 70 ...
... less than 7 feet . Section R - 205 - Room Sizes Every dwelling unit shall have at least one habitable room which shall have not less than 150 square feet of floor area . Other habitable rooms shall have an area of not less than 70 ...
Page 94
... less cementing material than that specified for a solidly cemented base ply . R - 808.3 — Membrane Over Base Ply . A minimum of two successive layers of roofing plies shall be solidly cemented shingle fashion to the base ply , using no less ...
... less cementing material than that specified for a solidly cemented base ply . R - 808.3 — Membrane Over Base Ply . A minimum of two successive layers of roofing plies shall be solidly cemented shingle fashion to the base ply , using no less ...
Page 208
... less than 2,500 psi and a thickness of not less than 5 inches . The length of any unreinforced wall section shall not exceed 6 feet , and covers shall be reinforced in accordance with Table No. P - 2506.2 . Septic tanks shall be ...
... less than 2,500 psi and a thickness of not less than 5 inches . The length of any unreinforced wall section shall not exceed 6 feet , and covers shall be reinforced in accordance with Table No. P - 2506.2 . Septic tanks shall be ...
Contents
Part IADMINISTRATIVE | 1 |
CHAPTER 3Foundations | 19 |
CHAPTER 4Wall Construction | 27 |
43 other sections not shown
Other editions - View all
Common terms and phrases
12 inches ALLOWABLE SPAN ANSI appliance applied approved ASTM authority having jurisdiction Available for Friction³ based on stress building official cement chimney Chlorinated Polyvinyl Chloride clearance concrete conform connected connector construction designed diameter drain drainage dry or surfaced ducts Enter table Extreme Fiber Stress feet fireplace floor foot foundation walls furnace grout Gypsum HEADER inch is shown inspection joints joists lath less live load located lumber manufactured home material maximum metal minimum modulus of elasticity nail NOMINAL PIPE SIZE opening outlet Particleboard percent Piping Materials Plastic Pipe plumbing fixtures plywood portland cement pounds per square rafters upper figure reinforcement roof Section Select Structural sewer sheathing shingles soil spacing first column specifications square inch stack Standard 2x4 Steel Stress in Bending Stud supported Surfaced dry surfaced green table with span tank thickness trap Type values valve venting systems vertical vinyl chloride water closet Wood