Uniform Building Code, Volume 8International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 37
Page 307
... PORTLAND CEMENT Based on Standard Specifications C150-62 and C175-66 of the American Society for Testing and Materials See Section 2604 , Uniform Building Code , Volume ... Portland Cement Standard Specifications C150-62 C175-66 of the ASTM.
... PORTLAND CEMENT Based on Standard Specifications C150-62 and C175-66 of the American Society for Testing and Materials See Section 2604 , Uniform Building Code , Volume ... Portland Cement Standard Specifications C150-62 C175-66 of the ASTM.
Page 310
... cement will be made only at three and seven days . If a seven - day test is required on Type III cement , the ... PORTLAND BLAST - FURNACE SLAG CEMENT Based on Tentative Specification C205-62T of the American Society for Testing and ...
... cement will be made only at three and seven days . If a seven - day test is required on Type III cement , the ... PORTLAND BLAST - FURNACE SLAG CEMENT Based on Tentative Specification C205-62T of the American Society for Testing and ...
Page 311
... Portland blast - furnace slag cement of the type Chemical specified shall conform to the chemical requirements prescribed in Requirements Table No. 26-1 - A . The ... Portland-Pozzolan Cement Standard Specification C340- 62T of the ASTM.
... Portland blast - furnace slag cement of the type Chemical specified shall conform to the chemical requirements prescribed in Requirements Table No. 26-1 - A . The ... Portland-Pozzolan Cement Standard Specification C340- 62T of the ASTM.
Contents
ternational Conference of Building Officials | 16 |
CHAPTER | 29 |
CHAPTER 24 | 50 |
Copyright | |
17 other sections not shown
Other editions - View all
Common terms and phrases
adhesive admixture aggregate allowable load angle apply approximately average bars beams bending bolt BUILDING CODE STANDARD butt joints cent Characteristics and limiting chord compression members compressive strength concrete conform Continued diameter dimension distance Douglas fir edge end joints exceed feet fillet flammable liquids flange flexural glue glued grade gypsum holes Joists and Planks knots lag screw laminations length less lumber masonry maximum measured minimum mixing mortar nails narrow face nominal one-half inch panel parallel to grain permitted piece Pine pitch pockets plywood portland cement pounds per square pozzolan requirements sample scarf joints shake shear shear strength slabs slope of grain spaced species specified splice plate splits square inch steel strength ratio Structural surface Table tabulated loads tanks temperature tensile tensile strength tension test specimens thickness tion U.B.C. Standard Uniform Building Code unit stresses veneer Volume I Sec welds wide face wire