Uniform Building Code Standards |
From inside the book
Results 1-3 of 73
Page 117
... limiting provisions apply to all grades and sizes of lumber used as individual laminations for structural glued ... provisions for " L1 - c " except that dense material is required and slope of grain is limited to 1 in 14 . 2. “ L1 - c ...
... limiting provisions apply to all grades and sizes of lumber used as individual laminations for structural glued ... provisions for " L1 - c " except that dense material is required and slope of grain is limited to 1 in 14 . 2. “ L1 - c ...
Page 149
... limiting provisions on the back and unexposed edges are : Hit - and- miss skips ; wane one third the width and other characteristics not interfering with the intended use of the grade . ( c ) Commercial Decking . Characteristics and ...
... limiting provisions on the back and unexposed edges are : Hit - and- miss skips ; wane one third the width and other characteristics not interfering with the intended use of the grade . ( c ) Commercial Decking . Characteristics and ...
Page 150
... limiting provisions on the back and unexposed edges are : Wane approximately one third of the face and other characteristics not interfering with the intended use are permitted on unexposed back and edges , except as noted . Any piece ...
... limiting provisions on the back and unexposed edges are : Wane approximately one third of the face and other characteristics not interfering with the intended use are permitted on unexposed back and edges , except as noted . Any piece ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone