Uniform Building Code Standards |
From inside the book
Results 1-3 of 45
Page 59
... mortar mixed and tested in the laboratory . 2. Proportion specifications . Proportion specifications are those in which the accept- ability of the mortar is based on the properties of the ingredients ( materials ) and a definite ...
... mortar mixed and tested in the laboratory . 2. Proportion specifications . Proportion specifications are those in which the accept- ability of the mortar is based on the properties of the ingredients ( materials ) and a definite ...
Page 60
... mortar may be permitted on small jobs , with the written approval of the hand mixing procedure by the building official . Mortar Sec . 24.2004 . ( a ) Mortar for Unit Masonry . Mortar conforming to the proportion specifications shall ...
... mortar may be permitted on small jobs , with the written approval of the hand mixing procedure by the building official . Mortar Sec . 24.2004 . ( a ) Mortar for Unit Masonry . Mortar conforming to the proportion specifications shall ...
Page 63
... MORTAR Based on Standard Specification C144-76 of the American Society for Testing and Materials See Section 2402 ( b ) 1 , Uniform Building Code Scope Sec . 24.2101 . This standard covers aggregate for use in masonry mortar . Material ...
... MORTAR Based on Standard Specification C144-76 of the American Society for Testing and Materials See Section 2402 ( b ) 1 , Uniform Building Code Scope Sec . 24.2101 . This standard covers aggregate for use in masonry mortar . Material ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone