Uniform Building Code Standards |
From inside the book
Results 1-3 of 85
Page 170
... test panels and five of the overlaid test panels , 51 / 2inch by 8 - inch specimens shall be cut and tested as described in Subsection 25.915 ( d ) . Test for Interior - type Plywood Sec . 25.913 . The test specimens prepared as ...
... test panels and five of the overlaid test panels , 51 / 2inch by 8 - inch specimens shall be cut and tested as described in Subsection 25.915 ( d ) . Test for Interior - type Plywood Sec . 25.913 . The test specimens prepared as ...
Page 492
... test may be used to satisfy the daily test requirement for the radius repair procedure . A minimum of 10 specimens shall be cut through the test block glue line ( s ) and tested . ( d ) Adhesives . Adhesive batch or lot tests prior to ...
... test may be used to satisfy the daily test requirement for the radius repair procedure . A minimum of 10 specimens shall be cut through the test block glue line ( s ) and tested . ( d ) Adhesives . Adhesive batch or lot tests prior to ...
Page 570
... test shall not exceed 0.5 . Mixing Sec . 26.909 . Machine mix the concrete as prescribed in Part I of U.B.C. Standard No. 26-10 . Tests and Properties of Freshly Mixed Concrete ... Test specimens shall be made and 570 26-9 U.B.C. STANDARDS.
... test shall not exceed 0.5 . Mixing Sec . 26.909 . Machine mix the concrete as prescribed in Part I of U.B.C. Standard No. 26-10 . Tests and Properties of Freshly Mixed Concrete ... Test specimens shall be made and 570 26-9 U.B.C. STANDARDS.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone