Uniform Building Code Standards |
From inside the book
Results 1-3 of 44
Page 158
... veneer used for inner plies may be stitched . Stitched veneer used for outer plies is limited to panels with C or D grade faces or backs , except stitched C veneer may not be used for faces in decorative panels . Panels may have face or ...
... veneer used for inner plies may be stitched . Stitched veneer used for outer plies is limited to panels with C or D grade faces or backs , except stitched C veneer may not be used for faces in decorative panels . Panels may have face or ...
Page 1159
... VENEER PLASTER AND GYPSUM VENEER PLASTER Based on Standard Specifications C588-68 and C587-73 of the American Society for Testing and Materials See Tables Nos . 43 - A , 43 - B and 43 - C , Uniform Building Code Scope Part - Gypsum ...
... VENEER PLASTER AND GYPSUM VENEER PLASTER Based on Standard Specifications C588-68 and C587-73 of the American Society for Testing and Materials See Tables Nos . 43 - A , 43 - B and 43 - C , Uniform Building Code Scope Part - Gypsum ...
Page 1189
... veneer plaster , or other cementitious material compatible with the veneer plaster or by using self - adhering strip reinforcement . When stapling , staples shall be used along the ceiling edge only for wall - to - ceiling angles and ...
... veneer plaster , or other cementitious material compatible with the veneer plaster or by using self - adhering strip reinforcement . When stapling , staples shall be used along the ceiling edge only for wall - to - ceiling angles and ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone