... Sample It seemed desirable to have a working standard sample which , once calibrated with an absolute method , would permit the rapid determina- tion of the absolute intensity by comparing its scattering quantitatively with the ...
... Sample It seemed desirable to have a working standard sample which , once calibrated with an absolute method , would permit the rapid determina- tion of the absolute intensity by comparing its scattering quantitatively with the ...
Page 269
... sample volume was such that the decay of the free precessional signal was approximately 2 msec . The sample coil , 3.0 cm in length , was wound on a glass tube of 7 mm inner diameter and was positioned , with its axis vertical , in the ...
... sample volume was such that the decay of the free precessional signal was approximately 2 msec . The sample coil , 3.0 cm in length , was wound on a glass tube of 7 mm inner diameter and was positioned , with its axis vertical , in the ...
Page 295
... sample preparation , the bulk wool and hair had been cleaned by washing in ether ( to remove natural oils ) and in distilled water . In the case of rhinoceros horn , the cleaning took place after the sample was cut . The cleaned and ...
... sample preparation , the bulk wool and hair had been cleaned by washing in ether ( to remove natural oils ) and in distilled water . In the case of rhinoceros horn , the cleaning took place after the sample was cut . The cleaned and ...
Contents
Direct Volume Change | 22 |
Density | 32 |
Derivation of the Partial Specific Volume from | 62 |
Copyright | |
47 other sections not shown
Other editions - View all
Common terms and phrases
a-helix absorption acid Acta angle axial ratio B-structure Biochem Biochemistry Biol buffer c₂ calculated CD spectra Chem chromophore circular dichroism coefficient conformation constant Cotton effects cross-section curves denaturation determined dialyzate diffusible components dilute electron density ellipsoids ellipticity enzyme equation equilibrium exciton factor function gm/ml grams Guinier helical helix hemocyanin hemoglobin intensity interaction investigated Kratky lysozyme macromolecule magnetic measurements membrane method mg/ml molal molecular weight molecule myoglobin negative nondiffusible obtained optical activity osmometers osmotic pressure parameter partial specific volume particles peptide Phys Pilz plot polymer polypeptides Porod primary beam procedure protein component protein solution radii radius of gyration residues rotational strength sample Schellman Section shape small-angle scattering small-angle X-ray scattering solvent solvent medium spectrum structure studies subsidiary maxima subunits T₁ temperature theoretical scattering curves Tinoco tion transition v₂ wavelength zero