Uniform Building Code, Volume 5International Conference of Building Officials., 1970 - Building laws |
From inside the book
Results 1-3 of 3
Page 14
EXCEPTIONS : 1. ... Over 3600 18 i 14 14 Plain , Plate or Wired Plain , Plate or Wired Plain , Plate or Wired Wired Glass 144 Over 144 EXCEPTION : Sections of approved plastics on signs Construction other 14 SECTION S - 402 U.B.C. VOL .
EXCEPTIONS : 1. ... Over 3600 18 i 14 14 Plain , Plate or Wired Plain , Plate or Wired Plain , Plate or Wired Wired Glass 144 Over 144 EXCEPTION : Sections of approved plastics on signs Construction other 14 SECTION S - 402 U.B.C. VOL .
Page 15
EXCEPTION : Sections of approved plastics on signs Construction other than wall signs may not be required to be separated ( Continued ) if approved by the Building Official . ( g ) Approved Plastics . The Building Official shall require ...
EXCEPTION : Sections of approved plastics on signs Construction other than wall signs may not be required to be separated ( Continued ) if approved by the Building Official . ( g ) Approved Plastics . The Building Official shall require ...
Page 20
EXCEPTION : Temporary cloth signs over private property not exceeding 60 square feet shall be supported and attached with wire rope which will meet the requirements of Chapter 4 of this Code . ( b ) Projection .
EXCEPTION : Temporary cloth signs over private property not exceeding 60 square feet shall be supported and attached with wire rope which will meet the requirements of Chapter 4 of this Code . ( b ) Projection .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Common terms and phrases
advertising alley anchorage Anchors applied approved plastics attached authorized Building Official building or structure Clearance Cloth signs Combination signs conductors conform connection constructed Continued curb designed in accordance display surface electric signs Enforcement entry erected established exceed EXCEPTION extend feet feet above grade Fin signs Fire forces formed frame gauge GLASS greater Ground signs height horizontal inches Inspections intended legal setback line less light located manner MAXIMUM meet the requirements noncombustible materials opening owner painted parapet permit person placed pole signs portion private property PROJECTING SIGN projects over public proper public property reasonable regulating representative requirements requirements specified resist Roof signs seismic loads separate sign or sign sign structure signs and sign SIGNS Sec soil specified in Chapter square feet Stanford steel street stresses supports Table Temporary signs tested thickness tion trim TYPE U.B.C. Standard Uniform Building Code vertical violation Volume wall signs wind wood