Advanced Neutron Sources 1988, Proceedings of the 10th Meeting of the INT Collaboration on Advanced Neutron Sources (ICANS X), Held at Los Alamos, October 1988Revolving around the interaction between spectrometer and target-station design and performance, this volume emphasises the need for feedback that must exist between scientific requirements and source design. It achieves a forum for the sharing of information on the development of spallation neutron sources. Of great value to researchers in condensed matter physics, instrumentation and data processing involved in neutron scattering at pulsed and steady sources. |
From inside the book
Results 1-3 of 59
Page 19
... energy transfer spectrometer Multi - angle rotor instrument Time - focused crystal analyser High - resolution ... energy 50-2000 meV € range 20-1000 meV 1 % energy transfer resolution . Chopper ; incident energy 20-1000 meV e range 10 ...
... energy transfer spectrometer Multi - angle rotor instrument Time - focused crystal analyser High - resolution ... energy 50-2000 meV € range 20-1000 meV 1 % energy transfer resolution . Chopper ; incident energy 20-1000 meV e range 10 ...
Page 282
... energy transfers ( 0-10 meV ) [ 11 ] . It was commissioned during the second half of 1987 and is now in routine ... transfer range is required . At full ISIS frequency the wavelength window at the sample is 2.0 Å . The energy transfer ...
... energy transfers ( 0-10 meV ) [ 11 ] . It was commissioned during the second half of 1987 and is now in routine ... transfer range is required . At full ISIS frequency the wavelength window at the sample is 2.0 Å . The energy transfer ...
Page 289
... energy transfer scattering at low values of associated momentum transfer using ( n , y ) detectors [ 15 ] . A review held in Spring 1988 concluded that below 500 meV transfer , chopper spectrometers such as HET had significantly better ...
... energy transfer scattering at low values of associated momentum transfer using ( n , y ) detectors [ 15 ] . A review held in Spring 1988 concluded that below 500 meV transfer , chopper spectrometers such as HET had significantly better ...
Contents
Monday October 3 1988 | 9 |
Tuesday October 4 1988 | 135 |
Wednesday October 5 1988 | 609 |
Copyright | |
2 other sections not shown
Other editions - View all
Common terms and phrases
accelerator Advanced Neutron Sources analysis angular background beam line Brillouin scattering calculated chopper cold neutron cold source collimators count rate cross section crystal data acquisition deconvolution decoupled density detector deuterium diffraction diffractometer distribution dose effective energy transfer experimental experiments facility factor Figure fission flight path foil function gamma Gaussian geometry high-energy histogram improve increase inelastic injection instrument intensity IPNS ISIS LAMPF leakage liquid hydrogen Los Alamos magnetic material MaxEnt maximum measured methane module Monte Carlo neutron beam neutron flux neutron scattering Nucl Nuclear obtained operation optimization parameters peak performance Phys position present problems produced proton proton beam radiation radius range reactor reconstruction reflector resolution Rutherford Appleton Laboratory sample scattering angle shield shown in Fig shows solid methane spallation neutron source spallation source spectra spectrometer spectrum surface temperature thermal neutron thick time-of-flight tube wavelength width