Advanced Neutron Sources 1988, Proceedings of the 10th Meeting of the INT Collaboration on Advanced Neutron Sources (ICANS X), Held at Los Alamos, October 1988Revolving around the interaction between spectrometer and target-station design and performance, this volume emphasises the need for feedback that must exist between scientific requirements and source design. It achieves a forum for the sharing of information on the development of spallation neutron sources. Of great value to researchers in condensed matter physics, instrumentation and data processing involved in neutron scattering at pulsed and steady sources. |
From inside the book
Results 1-3 of 23
Page 437
... Histogram every 20 μsec the average data rate per or 1666 events per IPNS pulse . Since each the peak data rate per module can be much detector dead time for a burst of at least Histogram Accelerator The FASTDAS Histogram Accelerator ...
... Histogram every 20 μsec the average data rate per or 1666 events per IPNS pulse . Since each the peak data rate per module can be much detector dead time for a burst of at least Histogram Accelerator The FASTDAS Histogram Accelerator ...
Page 438
... HISTOGRAM TYPE LOOKUP TIME- DEP . OFFSET Fig . 8 Block diagram of the FASTDAS Histogram Accelerator . The focus and time- delay options are not intended for use with GLAD , but are included for compatibility with other IPNS instruments ...
... HISTOGRAM TYPE LOOKUP TIME- DEP . OFFSET Fig . 8 Block diagram of the FASTDAS Histogram Accelerator . The focus and time- delay options are not intended for use with GLAD , but are included for compatibility with other IPNS instruments ...
Page 439
... Histogram Accelerator has completed all required histograming for this event it immediately requests another event from the auxiliary - crate- controller FIFO , so the Histogram Accelerator is the controlling factor in the overall ...
... Histogram Accelerator has completed all required histograming for this event it immediately requests another event from the auxiliary - crate- controller FIFO , so the Histogram Accelerator is the controlling factor in the overall ...
Contents
Monday October 3 1988 | 9 |
Tuesday October 4 1988 | 135 |
Wednesday October 5 1988 | 609 |
Copyright | |
2 other sections not shown
Other editions - View all
Common terms and phrases
accelerator Advanced Neutron Sources analysis angular background beam line Brillouin scattering calculated chopper cold neutron cold source collimators count rate cross section crystal data acquisition deconvolution decoupled density detector deuterium diffraction diffractometer distribution dose effective energy transfer experimental experiments facility factor Figure fission flight path foil function gamma Gaussian geometry high-energy histogram improve increase inelastic injection instrument intensity IPNS ISIS LAMPF leakage liquid hydrogen Los Alamos magnetic material MaxEnt maximum measured methane module Monte Carlo neutron beam neutron flux neutron scattering Nucl Nuclear obtained operation optimization parameters peak performance Phys position present problems produced proton proton beam radiation radius range reactor reconstruction reflector resolution Rutherford Appleton Laboratory sample scattering angle shield shown in Fig shows solid methane spallation neutron source spallation source spectra spectrometer spectrum surface temperature thermal neutron thick time-of-flight tube wavelength width