Page 31
The investigation revealed that the longitudinal weld seam failures were due to a
high temperature stress rupture . Heavy carburisation had developed at the inner
walls . The material showed reduced ductility . In contrast , the Incoloy alloy 800 ...
The investigation revealed that the longitudinal weld seam failures were due to a
high temperature stress rupture . Heavy carburisation had developed at the inner
walls . The material showed reduced ductility . In contrast , the Incoloy alloy 800 ...
Page 135
5 percent arsenic has a higher strength and fatigue limit but still retains ductility .
Its main use is in condensers and heat exchangers for use in fresh water . It is not
recommended for waters containing hydrogen sulphide and other sulphur ...
5 percent arsenic has a higher strength and fatigue limit but still retains ductility .
Its main use is in condensers and heat exchangers for use in fresh water . It is not
recommended for waters containing hydrogen sulphide and other sulphur ...
Page 147
Table 1 Humidity Sulphur pollution Rate of corrosion , mils / yr . More than 70° . 0
. 5 1 . 0 n 3 . 7 2 . 3 2 . 4 Comparative performances of the different materials
Steel for its versatile properties of strength and ductility and also for its cheapness
is ...
Table 1 Humidity Sulphur pollution Rate of corrosion , mils / yr . More than 70° . 0
. 5 1 . 0 n 3 . 7 2 . 3 2 . 4 Comparative performances of the different materials
Steel for its versatile properties of strength and ductility and also for its cheapness
is ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
INTRODUCTION | 3 |
CHEMICAL CORROSION AND ITS PREVENTION | 13 |
DISCUSSION | 22 |
9 other sections not shown
Common terms and phrases
addition alloys aluminium ammonia ammonium amount anodic application attack bottom carbon steel cast iron cathodic protection cause chemical chloride chromium coatings concentration construction containing cooling corrosion problems corrosion rate cracking crude developed distillation effective environment epoxy equipment exchangers failure fertiliser flow give given handling heat hydrogen hydrogen sulphide increase industry inhibitor iron lead less material metal method mild steel Monel months natural observed occurred operating organic oxide oxygen paint petroleum phosphate pipe pitting plant plates potential practice presence pressure prevent pumps range reaction reduced refinery removal resistance rubber severe shell showing solution specially stainless steel steam storage tanks stress corrosion structure suitable sulphuric acid surface Table tanks temperature tests thickness tower treatment tubes unit various welding zinc