Page 136
In preventing local attack or general corrosion , inhibitors and restrainers serve a
number of other desirable functions . ... In a slightly hard stagnant supply water
over 2000 ppm chromate were required to prevent attack on abraded mild steel ...
In preventing local attack or general corrosion , inhibitors and restrainers serve a
number of other desirable functions . ... In a slightly hard stagnant supply water
over 2000 ppm chromate were required to prevent attack on abraded mild steel ...
Page 137
Excellent results have been obtained in preventing attack on mild steel by
solutions containing upto 1 , 500 ppm chloride ion by adding polyphosphate at a
concentration of 50 ppm ( as P , Os ) and calcium or zinc at a concentration of 30
ppm .
Excellent results have been obtained in preventing attack on mild steel by
solutions containing upto 1 , 500 ppm chloride ion by adding polyphosphate at a
concentration of 50 ppm ( as P , Os ) and calcium or zinc at a concentration of 30
ppm .
Page 138
Chlorination which is carried out to prevent algae growth may increase corrosion
if the concentration rises about 0 . 4 ppm . Concentration by evaporation may
increase the original chloride and sulphate content to a level as high as 10 times
...
Chlorination which is carried out to prevent algae growth may increase corrosion
if the concentration rises about 0 . 4 ppm . Concentration by evaporation may
increase the original chloride and sulphate content to a level as high as 10 times
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
INTRODUCTION | 3 |
CHEMICAL CORROSION AND ITS PREVENTION | 13 |
DISCUSSION | 22 |
9 other sections not shown
Common terms and phrases
addition alloys aluminium ammonia ammonium amount anodic application attack bottom carbon steel cast iron cathodic protection cause chemical chloride chromium coatings concentration construction containing cooling corrosion problems corrosion rate cracking crude developed distillation effective environment epoxy equipment exchangers failure fertiliser flow give given handling heat hydrogen hydrogen sulphide increase industry inhibitor iron lead less material metal method mild steel Monel months natural observed occurred operating organic oxide oxygen paint petroleum phosphate pipe pitting plant plates potential practice presence pressure prevent pumps range reaction reduced refinery removal resistance rubber severe shell showing solution specially stainless steel steam storage tanks stress corrosion structure suitable sulphuric acid surface Table tanks temperature tests thickness tower treatment tubes unit various welding zinc