Uniform Building Code, Volume 6International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 6
Page 31
... course of all corbels shall be a header course . [ Sec . 2416 ( b ) . ] GROUTED MASONRY General ( See Figure No. 10 , page 61. ) Grouted masonry is that form of construction made with brick or solid concrete brick units in which ...
... course of all corbels shall be a header course . [ Sec . 2416 ( b ) . ] GROUTED MASONRY General ( See Figure No. 10 , page 61. ) Grouted masonry is that form of construction made with brick or solid concrete brick units in which ...
Page 33
... courses shall be bonded at vertical intervals not exceeding thirty - four inches ( 34 " ) by lapping at least four inches ( 4 " ) over the unit below or by lapping at vertical intervals not exceeding seventeen inches ( 17 " ) with units ...
... courses shall be bonded at vertical intervals not exceeding thirty - four inches ( 34 " ) by lapping at least four inches ( 4 " ) over the unit below or by lapping at vertical intervals not exceeding seventeen inches ( 17 " ) with units ...
Page 50
... courses . Shakes shall be laid in straight or staggered courses with either fifteen inch ( 15 " ) or eighteen - inch ( 18 " ) wide strips of 30 - pound minimum felt shingled between each course in such a manner that no felt is exposed ...
... courses . Shakes shall be laid in straight or staggered courses with either fifteen inch ( 15 " ) or eighteen - inch ( 18 " ) wide strips of 30 - pound minimum felt shingled between each course in such a manner that no felt is exposed ...
Contents
LEGAL REQUIREMENTS | 5 |
FRAMING GENERAL | 12 |
WALL FRAMING WOOD | 20 |
Copyright | |
5 other sections not shown
Other editions - View all
Common terms and phrases
11 gauge ALLOWABLE SPAN Feet anchored applied approved base coats BOLTS bond Building Official cavity walls Ceiling Ceiling Ceiling CEILING JOISTS concrete corrosion-resistant Dead load Direction 24 Douglas Fir edges exceed Expanded Metal Lath exterior walls face nail Fasteners finish coat Fire-resistive Construction FIRESTOP Foundation four inches GRADE Group Group Group GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster less than four LINTEL live load MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum thickness modulus of elasticity mortar Particleboard partitions PLATE portland cement plaster pounds per square ROOF RAFTERS second coat six inches square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction water closet width wire fabric lath wood shingles